• >정보자료실
  • >논문자료
  • >
샘플러에 따른 측정 위치별 원소탄소의 농도 비율
글쓴이 관리자 (IP: *.223.176.122) 작성일 2022-02-09 13:45 조회수 276

샘플러에 따른 측정 위치별 원소탄소의 농도 비율

Ratio of Elemental Carbon Concentrations for Respective Measurement Locations according to the Sampler

 

ABSTRACT

Objectives: This study was conducted to determine the differences in EC concentrations according to the type of sampler by measuring and analyzing EC. 

Methods: Elemental carbon was measured in diesel engine vehicles and at the roadside. Using NIOSH method 5040, a cassette was coupled to 37 ㎜ and 27 ㎜ quartz filters and measurements were performed 21 times. There were 14 types of measurement methods, and polystyrene, polypropylene, and metal samplers were evenly placed inside the movable chamber. 

Results: The results measured using the 37 ㎜ conductive cassette (closed/open) and the IOM sampler made of conductive materials showed a higher ratio than the other results. When the 37 ㎜ conductive cassette was measured with the lid open, it showed a statistically significantly higher ratio than with other measurement methods (p<0.05). 

Conclusions: Checking the EC concentration a total of 21 times at each ratio based on the concentration of the 3-stage polystyrene cassette, it was statistically significantly higher when the 37 ㎜ conductive cassette was open. This same cassette also showed a slightly higher EC concentration when closed. It was ascertained that some DEE was collected on the cassette wall surface due to the electrical conductivity of the polystyrene cassette, resulting in sample loss. Since EC is composed of fine particles, it is thought that electrical conductivity may affect its concentration.

 

Key words

Diesel engine exhaust, elemental carbon, electrical conductivity

 

▶출처 : 한국산업보건학회지, 제31권 제4호

파일 샘플러에 따른 측정 위치별 원소탄소의 농도 비율.pdf(599.4K)