이젝터-다공튜브 희석 샘플링과 ELPI를 이용한 석탄화력발전소 배출 미세먼지의 입자 크기에 따른 성분 분석 | |||||
---|---|---|---|---|---|
글쓴이 | 관리자 (IP: *.223.176.122) | 작성일 | 2022-11-07 15:48 | 조회수 | 180 |
이젝터-다공튜브 희석 샘플링과 ELPI를 이용한 석탄화력발전소 배출 미세먼지의 입자 크기에 따른 성분 분석 Elemental components analysis according to the size of fine particles emitted from a coal-fired power plant using an ejector-porous tube dilution sampling and ELPI
Abstract In order to understand the characteristics of fine particles emitted from coal-fired power plant stacks, it is important to analyze the size distribution and components of particles. In this study, particle size distributions were measured using the ejector-porous tube dilution device and an ELPI system at a stack in a coal-fired power plant. Main elemental components of particles in each size interval were also identified through TEM-EDS analysis for the particles collected in each ELPI stage. Particle size distributions based on number and mass were analyzed with component distributions from 0.006 to 10 μm. The highest number concentration was about 0.01 μm. The main component of the particles consisted of sulfur, which indicated that sulfate aerosols were generated by gas-to-particle conversion of SO2. In a mass size distribution, a mono-modal distribution with a mode diameter of about 2 μm was shown. For the components of PM1.0 (particles less than 1 μm), the abundance order was F > Mg > S > Ca, and however, for the components of PM10 (particles less than 10 μm), it was in the order of Fe > S > Ca > Mg. The elemental components by particle size were confirmed.
Key words fine particles, ELPI, coal-fired power plant, elemental componets, TEM-EDS
▶출처 : 한국입자에어로졸학회 Vol. 18, No. 3: September 2022 pp. 69-77 |
|||||
파일 | 이젝터-다공튜브 희석 샘플링과 ELPI를 이용한 석탄화력발전소 배출 미세먼지의 입자 크기에 따른 성분 분석.pdf(667.5K) |